The Entube-Z generates a ± 2 V or ± 1 V scaled down version of its input signal, which can then be processed by most computer based measurement platforms.
Eletronical | 100 z | 200 z | 300 z | 400 z | 500 z | 750 z | 1000 z | 2000 z | 3000 z | 4000 z | 5000 z |
Scaling Factor (2V output voltage) | 50 : 1 | 100 : 1 | 150 : 1 | 200 : 1 | 250 : 1 | 375 : 1 | 500 : 1 | 1000 : 1 | 1500 : 1 | 2000 : 1 | 2500 : 1 |
Input dynamic range (Working Voltage) | 100 V | 200 V | 300 V | 400 V | 500 V | 750 V | 1000 V | 2000 V | 3000 V | 4000 V | 5000 V |
Max Peak Surge Voltage (50Hz sinewave for 100ms) | 2 kV | 5 kV | 10 kV | 15 kV | 15 kV | 20 kV | > 25 kV | ||||
Input impedance at 50Hz | > 5 MΩ | > 10 MΩ | > 10 MΩ | > 20 MΩ | > 30 MΩ | > 40 MΩ | > 50 MΩ |
Accuracy | ± 0.5 % |
Max total phase shift at 50Hz | < 0.05° |
Output Offset Voltage (Referenced to output) | < ± 10 μV |
Output connector | BNC (Plug) |
Gain temperature drift | ± 100 ppm/°C |
Bandwidth (-3dB point) | 50 MHz |
Input-Output non-linearity | < 250 ppm |
Output voltage | ± 1 V or ± 2 V |
Output type | Single-ended signal |
The Entube-Z is a high bandwidth voltage transducer designed for single ended measurements in a very compact form factor, and without need for power supplies. This series covers the ranges of ± 100 V, ± 200 V, ± 300 V, ± 400 V, ± 500 V, ± 750 V, ± 1 kV, ± 2 kV, ±3 kV, ± 4 kV and ± 5 kV with up to 50 MHz bandwidth and 0.5 % of signal accuracy.
The Entube-Z generates a ± 2 V or ± 1 V scaled down version of its input signal, which can then be processed by most computer based measurement platforms.
The Entube Z sensor family operates as a single ended voltage divider that outputs a ± 2 V or ± 1 V output signal, which can be processed by a computer based measurement platform.
The coaxial input line connect to the sensor via a SHV or BNC connector, while the conditioned signal from the sensor comes out on a standard BNC Plug.
Due to its compact size and shape, the Entube Z sensor family can be easily mounted anywhere between the signal source and the data acquisition system. The versions up to 5kV may even be used inline with the cable and not require any mounting at all. All can be secured to fixtures using cable ties.