The IsoBand V has been designed to provide high-quality isolated differential voltage measurements for aplications requiring scaling of high voltages,as well as superior isolation.
Output (single ended):± 5 V, ± 10 V Bandwidth (-3dB point):8 MHz Output type:Single EndedThe IsoBand V has been designed to provide high-quality isolated differential voltage measurements for aplications requiring scaling of high voltages, as well as superior isolation.
Each IsoBand V unit hosts an isolated channel that can be connected to separate measurement sources while providing a range of functional coverage up to 1500V. The input has its own isolated reference, and can be configured to suit user needs. The output signal from the IsoBand V unit is referenced in respect to the ground channel of the user’s data acquisition system.
Designs its IsoBand V modules with consideration for user great flexibility, and low power consumption.
Input ranges | LR : ± 5 V, ± 10 V, ± 15 V, ± 20 V, ± 30 V MR : ± 50 V, ± 100 V, 150 VAC, 250 VAC, ± 300 V HR : ± 500 V, 500 VAC, ± 750 V, ± 1000 V, ± 1500 V, custom |
Bandwidth ( - 3dB point) | 8 MHz |
Input-Output non-linearity | < 0.04 % |
Output (single ended) | ± 5 V, ± 10 V |
Gain temperature drift | ± 50 ppm/°C |
Common mode rejection at 60Hz | 112 dB |
Output Offset current | 2σ < ± 500 μV (typical) 4σ < ± 1 mV (limit) |
Power Supply Voltage | 12 V to 36 V |
Output type | Single Ended |
Insulation impedance | > 10 GΩ || 2 pF |
Accuracy | ± 0.2% of reading + 0.005 % range |
Max total phase shift at 60Hz | < 0.004° |
Max latency | < 325 ns |
Isolation voltage from primary to secondary | > ± 1500 VAC |
Withstanding common mode surge voltage | ± 5000 V |
Withstanding differential surge voltage | ± 2500 V |
Operating temperature | – 25 to 70 °C |
Storage temperature | – 40 to 80 °C |
Mounting Type | DIN Rail |
Connectivity | Spring Cage connector |
Channels | 1 channel |
The IsoBand V module is designed to isolate and scale down high voltages found in industrial enviroments. The end result is a signal ready to connect to any data acquisition system.
The IsoBand V with surge protection and outstanding linearity, the scaled-down input signal is digitized,transformit in the digital domain.
After the digital isolation, digital bitstream will be reconstructed into an analog signal. Then,operation amplifier converts the signal
to ± 10 V range, The operation amplifier with an anti-aliasing filter. The ouput signal can be connected to data acquisition system or oscilloscope. The following diagram depicts the signal processing above.