Customer Support +86-755-26975359

IsoCap I-ST-1c

The IsoCap I-ST-1c is a sensor designed for high-quality isolated current measurements up to 100A mperes. The IsoCap I-ST-1c module provides 1500VAC primary-to-secondary sustained isolation, which allows users to monitor a miscellaneous of currents at different potentials.

Output voltage:±10V, ±5V   Output impedance:100Ω  Thermal drift gain:<±0.01%/°C


In Stock

YES

Delivery

10 Days

Warranty

24 months

Select Options

Input Current
Bandwidth
Accuracy
Output Voltage
- +
Add to inquiry form

Performance

Input ranges±10mA, ±20mA,  ±30mA, ±50mA, ±100mA,
±200mA, ±300mA, ±500mA, ±1A, ±2A, ±3A,
±4A, ±5A, ±10A, ±20A, ±30A, ±50A, ±60A, ±70A,
±80A, ±100A, 100A AC,custom
Input-Output non-linearity<280ppm/A
Gain temperature drift±50ppm/°C

Isolation voltage from

primary to secondary

>±2000V
Power Supply Voltage12Vto28V
Output typeDifferential signal
Output Offset Voltage2σ<±500μV (typical)
4σ<±1mV (limit)
Output impedance100Ω
Common mode impedance>2GΩ || 4pF
Max Input delay<5μs

Environmental

Operating temperature– 25 to 65°C
Storage temperature– 40 to 70°C
Mounting TypeDIN Rail
Weight86g (7.2oz)

Overview

The IsoCap I-ST-1c is a sensor designed for high-quality isolated current measurements up to 100 Amperes. The IsoCap I-ST-1c module provides 1500VAC primary-to-secondary sustained isolation, which allows users to monitor a miscellaneous of currents at different potentials. IsoCap I-ST-1c uses shunt methodology to measure the current flowing through the input conductor. In essence, this technique works by placing a high performance low impedance resistor along the current path (primary), while a galvanic isolation separates primary and secondary sides.
The compact form factor of the IsoCap I-ST-1c module allows users to setup high channel density monitoring systems, making it ideal for deployed and portable systems.

Environmental

Accuracy (percentage of reading)±( 0.2% of reading + 0.005% range)
±( 0.1% of reading + 0.005% range
Max total phase shift at 50Hz<0.05°
Max Input delay<5μs
Isolation voltage from
primary to secondary
 >±2000V
Withstanding common
mode surge voltage (1min)
±5000V
Thermal drift gain<±0.01%/°C

Hardware description

The current input connector is located at the top of the module in the figure bellow. A connector that servers to power the unit , output signal and ground the sensor lay along the bottom.

image.png


    image.png